ERROR CODES
___________________________________________________________________
Error No. Message / Action
10-8
than 125% of the channel rating.
060 Channel 1 high setpoint < low setpoint.
061 Channel 2 high setpoint < low setpoint.
062 Channel 3 high setpoint < low setpoint.
063 Channel 4 high setpoint < low setpoint.
The Peak tonnage high setpoint of the channel
indicated by the error code is set to a value less
than the low setpoint.
1) Adjust the high or low setpoint so that the high
setpoint is greater than the low setpoint.
064 Data window 1, channel 1 high setpoint too high.
065 Data window 1, channel 2 high setpoint too high.
066 Data window 1, channel 3 high setpoint too high.
067 Data window 1, channel 4 high setpoint too high.
The Data window 1 high setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.
1) Check the MACH RATING setting in the Config menu
for correctness.
2) Adjust the indicated setpoint to a setting less
than 125% of the channel rating.
068 Data window 1, channel 1 low setpoint too high.
069 Data window 1, channel 2 low setpoint too high.
070 Data window 1, channel 3 low setpoint too high.
071 Data window 1, channel 4 low setpoint too high.
The Data window 1 low setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.
1) Check the MACH RATING setting in the Config menu
for correctness.