LinkNet
LinkNet
Pressroom
Monitorin
g
Software
Installation and Operatin
g
Manual
Zobrazit stránku 0
1 2 3 4 5 6 ... 46 47

Shrnutí obsahu

Strany 1 - Software

LinkNetLinkNetPressroomMonitoringSoftwareInstallation and OperatingManual

Strany 2

LinkNet2.4 manual rev 2.1 March 25, 19992.3 System 1100 ConnectionsSystem 1100 tonnage monitors with softwareversions older than vers

Strany 3

LinkNet2.5 manual rev 2.1 March 25, 1999Figure 2.4: Regular Drop Box ConnectorsFigure 2.5: Repeater Drop Box ConnectionsWhenever poss

Strany 4

LinkNet2.6 manual rev 2.1 March 25, 1999The installation program will create a newprogram group called “LinkNet” and will put aLinkNe

Strany 5

LinkNet3.1 manual rev 2.1 March 25, 19993. Configuration After the software is installed, it must beconfigured. This consists of the

Strany 6

LinkNet3.2 manual rev 2.1 March 25, 1999Figure 3.3: Shift Configuration DialogEach day may have up to three shiftsconfigured. The “U

Strany 7

LinkNet3.3 manual rev 2.1 March 25, 1999then be sent to each press on the networkautomatically. 3.3.1 Adding a Down Time CodeTo Add

Strany 8

LinkNet3.4 manual rev 2.1 March 25, 1999Figure 3.6: Machine Configuration ListThis dialog allows machine to be added, edited,and dele

Strany 9

LinkNet3.5 manual rev 2.1 March 25, 1999Note that the idle condition will be activatedONLY if a down time code is not alreadyentered

Strany 10

LinkNet3.6 manual rev 2.1 March 25, 1999Figure 3.10: Die Configuration InformationEnter the machine number that this dieinformation a

Strany 11

LinkNet3.7 manual rev 2.1 March 25, 19993.5.3 Deleting DiesTo delete a die, select it the list Figure 3.9 andhit the “Delete Die” but

Strany 13

LinkNet3.8 manual rev 2.1 March 25, 1999engagements.PM can be set by machine or die. If set up bydie, the PM settings will be tracke

Strany 14

LinkNet3.9 manual rev 2.1 March 25, 1999anything desired.Hit the “Add PM Item” button and the dialog offigure 3.15 should be displaye

Strany 15

LinkNet3.10 manual rev 2.1 March 25, 19993.7.3 Resetting a Preventive Maintenance ItemWhen a PM has “tripped” (exceeded its limit), i

Strany 16

LinkNet4.1 manual rev 2.1 March 25, 1999Figure 4.1: Example Pressroom Overview Window4. Using LinkNet4.1 The Overview WindowWhen Link

Strany 17

LinkNet4.2 manual rev 2.1 March 25, 1999 minute poll is multiplied by the remaining parts tobe produced as given by the part counter

Strany 18

LinkNet4.3 manual rev 2.1 March 25, 1999Tuesday.The average tonnage, highest good tonnage, andlowest good tonnage are collected in 10

Strany 19

LinkNet4.4 manual rev 2.1 March 25, 19994.2.4 Tonnage DetailThe tonnage detail screen (“Peak Tons” tab - seeFigure 4.5) shows the ton

Strany 20

LinkNet5.1 manual rev 2.1 March 25, 19995. ReportsThere are several reports that can be generatedfrom the data that LinkNet collects.

Strany 21

LinkNet5.2 manual rev 2.1 March 25, 1999The event log is captured by day because of thelevel of detail. This allows for keeping only

Strany 22

LinkNet5.3 manual rev 2.1 March 25, 1999through, exported, or printed from the tool buttonsat the top of the report window. The thre

Strany 23

LinkNeti.1 manual rev 2.1 March 25, 1999Table of Contents1. Introduction...

Strany 24

LinkNet5.4 manual rev 2.1 March 25, 1999The graph shows the average tonnage, highestgood tonnage, and lowest good tonnage which areco

Strany 25

LinkNet5.5 manual rev 2.1 March 25, 1999Note that when a quick report is generated, itonly applies to the machine that was clicked on

Strany 26

LinkNet6.1 manual rev 2.1 March 25, 1999No two machines may have the same machinenumber or a machine number of 0!6. Using the OmniLin

Strany 27

LinkNet6.2 manual rev 2.1 March 25, 1999Note that the “NETWORK OPS” softkey andthe “Current DTC” message in the counterscreen will no

Strany 28

LinkNet6.3 manual rev 2.1 March 25, 1999If a down time code is active, whether automaticor operator entered, a “CLEAR DTC” softkey wi

Strany 29

LinkNet6.4 manual rev 2.1 March 25, 19996.5 Sending Tonnage Graphs from theOmniLink 5000LinkNet has the ability to receive and displa

Strany 30

LinkNet6.5 manual rev 2.1 March 25, 1999notes above. Hit the “MACHINE NOTES”softkey to view the machine notes again.

Strany 31

LinkNet7.1 manual rev 2.1 March 25, 1999No two machines may have the same machinenumber or a machine number of 0!Note that pressing t

Strany 32

LinkNet7.2 manual rev 2.1 March 25, 1999When a user entered DTC (not an automaticDTC) is active, the bar graphs beside eachchannel bl

Strany 33

LinkNet7.3 manual rev 2.1 March 25, 1999Note that the “NETWORK” menu will notappear if LinkNet is not running, if the System1100 ha

Strany 34

LinkNeti.2 manual rev 2.1 March 25, 19995. Reports ...5.15.1 T

Strany 35

LinkNet7.4 manual rev 2.1 March 25, 1999Use the up and down arrow keys to select“CLOCK” and hit the “ENTER” key.A screen with the cur

Strany 36

LinkNetA.1 manual rev 2.1 March 25, 1999If the OIT software version is older thanversion 2.0, the OIT and motherboard softwareMUST bo

Strany 37

LinkNetA.2 manual rev 2.1 March 25, 1999Figure A.1: System 1100 OIT Circuit BoardA.2.2 System 1100 Motherboard SoftwareUpgrade Proced

Strany 38

LinkNetA.3 manual rev 2.1 March 25, 1999A.3 OmniLink 5000 Upgrade ProcedureMost OmniLink 5000 press controls shippedprior to July 199

Strany 39

LinkNetA.4 manual rev 2.1 March 25, 1999Figure A.5:OIT to New CommunicationsBoard ConnectionsA.3.2 OmniLink OIT Software UpgradeProce

Strany 40

LinkNetA.5 manual rev 2.1 March 25, 1999Note that communications cards can have upto two additional software chips as options (afeed

Strany 41

LinkNetA.6 manual rev 2.1 March 25, 1999A.3.5 OmniLink Die Protection Module SoftwareUpgrade ProcedureThis upgrade procedure applies

Strany 42

LinkNetA.7 manual rev 2.1 March 25, 1999A.3.7 OmniLink Auto-Setup Module SoftwareUpgrade ProcedureThis upgrade procedure applies only

Strany 43

LinkNet1.1 manual rev 2.1 March 25, 19991. IntroductionThe Link Systems Network Application(LinkNet) provides detailed monitoring of

Strany 44

LinkNet1.2 manual rev 2.1 March 25, 1999At least one free RS232 serial portRecommended Hardware:Pentium II 333MHz CPU or better32MB m

Strany 45

LinkNet2.1 manual rev 2.1 March 25, 1999Figure 2.1: Daisy Chained Network Example2. InstallationLinkNet is connected to each piece of

Strany 46

LinkNet2.2 manual rev 2.1 March 25, 1999At the computer, an RS232 to RS485 converteris necessary. This converts the standard serial

Strany 47

LinkNet2.3 manual rev 2.1 March 25, 1999Belden 8103 cable and many similar cablesorganized as twisted pairs use a special color codes